A1446 Addressable Loop Interfaces

| Печать |


A1446

  • Ideal for use with all Control Equipment's Apollo protocol analogue addressable control panels
  • 3 inputs, prioritised in the protocol
  • 1 two-stage programmable alarm circuit rated 1 Amp @ 24V DC
  • 1 programmable relay rated 1 Amp @ 24V DC
  • Loop terminals with test probe locator
  • Normally Open or Normally Closed input selection
  • Selectable type code options
  • The A1447 Zone Module Adaptor board fits to the motherboard to change two of the inputs to fully monitored circuits
  • The highest quality of design, componentry and manufacture for outstanding durability
  • Uses the latest manufacturing technology to ensure consistency and reliability of product supply

Introduction

The Control Equipment range of loop interfaces are designed to allow remote monitoring of 3 voltage free contacts via the loop and communicate their status to the panel using analogue values.

The A1446 Sounder Controller Interface has a single change-over relay and fullymonitored sounder output circuit which can operate in pulsed or continuous mode. It requires a 24V DC supply.

The A1446 Sounder Controller Interface has a single change-over relay and fullymonitored sounder output circuit which can operate in pulsed or continuous mode. It requires a 24V DC supply.

 

Technical Specification

Supply Voltage: 17-25V loop derived & from separate PSE
Quiescent Current: 1.0mA loop derived + 0.5mA per active output
Input Terminals: Loop connections, 3 inputs for voltage-free contacts, external power supply
Analogue Values:

  • 64 - Input 1 operated;
  • 48 - Input 2 operated;
  • 4 - Fault Input operated or local fault;
  • 16 - Quiescent condition;

Local Power Supply Current: Quiescent condition: 10mA
Full alarm load: 800mA
Additional Input: Synchronised input
Outputs:

  • Change-over relay rated 1 Amp @ 24V DC
  • One monitored alarm circuit rated 750mA
  • Synchronised output

Part Numbers

2500/237 A1445 Relay Interface
2500/247 A1445 Relay Interface Boxed
2500/250 A1445/47 Relay Interface c/w Zone Monitor Unit Boxed
2500/253 A1445/47 Relay Interface & PSE Boxed
2500/256 A1445/47 Relay Interface c/w Zone Monitor Unit& PSE Boxed

 